LSI MegaRAID SAS 9361-8i(1GB»º´æ)
- RAID¹¦ÄÜ£ºRAID¼¶±ð0£¬1£¬5£¬6£¬10£¬50£¬60
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ×î¶àÁ¬½ÓÉ豸£ºÁ¬½Ó¶à´ï128¸öSATA»òSAS¶Ë¿Ú£¬¿¨´ø1G»º´æ
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£ºÊʺϰ²×°ÔÚ»ú¼ÜÉϵĵÍÆÊÃæµÄÐÎʽÒòËغ͸±·þÎñÆ÷°²×°SASÁ¬½ÓÆ÷ Ö§³Ö¹Ø¼ü£¬PCIe 3Á¬½Ó¸ß´ø¿íµÄÓ¦Óà Ìí¼Ó¸ü¶àµÄ±£»¤ºÍ¿ÉÑ¡µÄcachevaultÉÁ´æ»º´æ±£»¤ºÍƽµÄÐÄ̬
LSI MegaRAID SAS 9361-8i(2GB»º´æ)
- RAID¹¦ÄÜ£ºRAID¼¶±ð0£¬1£¬5£¬6£¬10£¬50£¬60
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ×î¶àÁ¬½ÓÉ豸£ºÁ¬½Ó¶à´ï128¸öSATA»òSAS¶Ë¿Ú£¬¿¨´ø2GB»º´æ
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£ºÊʺϰ²×°ÔÚ»ú¼ÜÉϵĵÍÆÊÃæµÄÐÎʽÒòËغ͸±·þÎñÆ÷°²×°SASÁ¬½ÓÆ÷ Ö§³Ö¹Ø¼ü£¬PCIe 3Á¬½Ó¸ß´ø¿íµÄÓ¦Óà Ìí¼Ó¸ü¶àµÄ±£»¤ºÍ¿ÉÑ¡µÄcachevaultÉÁ´æ»º´æ±£»¤ºÍƽµÄÐÄ̬
LSI MegaRAID SAS 9260-8i
- ºËÐÄ´¦ÀíоƬ£ºLSISAS2108 ROC
- RAID¹¦ÄÜ£ºRAID ¼¶±ð£º0¡¢1¡¢5 ºÍ 6 RAID À©Õ¹£º10¡¢50 ºÍ 60 ÔÚÏß RAID ¼¶±ðÉý¼¶ (RLM)
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º6Gb/s
- ×î¶àÁ¬½ÓÉ豸£º¿ÉÁ¬½Ó¶à´ï 32 ¸ö SATA ºÍ/»ò SAS Æ÷¼þ
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£º2 ¸öÃÔÄã SAS SFF-8087 x4 Á¬½ÓÆ÷ 8¸ö PCI Express 2.0 Ö÷»ú½Ó¿Ú 512MB DDRII ¸ßËÙ»º´æ (800MHz) ¿ÉÑ¡µç³Ø±¸·Ýµ¥Ôª£¨Ö±½ÓÁ¬½Ó£© Öؽ¨Ê±×Ô¶¯»Ö¸´ ¸Ä½¨Ê±×Ô¶¯»Ö¸´ ÔÚÏßÈÝÁ¿À©Õ¹ (OCE) SafeStore ¼ÓÃÜ·þÎñ ½èÖú SSD Guard Ìṩ SSD Ö§³Ö
- ²úÆ·ÌØÐÔ1£º¾ß±¸¿É»Ö¸´ÈÈ ¸ü¶à²ÎÊý>>
LSI 9311-8i
- Êý¾Ý´«ÊäÂÊ£º12 GB/ssas-3¼æÈÝ
- ϵͳƽ̨£ºMicrosoft Windows¡¢Linux(SUSE¡¢Red Hat)¡¢Solaris¡¢VMware¡¢FreeBSD
- ÆäËûÐÔÄÜ£ºÉúÃüÖÜÆÚ£ºÖ÷¶¯ Ö÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.0 ÎïÀíάÊý£ºµÍÂÖÀª(2.6¡°x6.0¡±) Ö§³Å×°Öãº1024 ÈÚºÏMPTÖ§¼Ü£º¾Û±äMPT™2.5 ÄÚ²¿Á¬½ÓÆ÷£º2 Mini-SAS HD SFF 8643 ²Ù×÷ζȣº0¡ãC-55¡ãC ¹¤×÷µçѹ£º+12V+/-8%£¬3.3V+/-9% PCIµçÔ´£º13W µçÀÂÖ§¼Ü£º¶Û»¯Í
- ²úÆ·ÌØÐÔ1£ºI/O¿ØÖÆÆ÷£ºLSI SAS 3008 MTBF£º>280ÍòСʱ ¹¤×÷ʪ¶È£º5%-90%²»Äý½á(ÆøÁ÷£º200 lfm) ÍмܣºÈ«¸ßµÍÂÖÀªÅÅÆø ±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö
LSI 9460-8i
- ÄÚÖýӿڣº2 Mini-SAS HD x4 SFF-8643
- ÆäËûÐÔÄÜ£º¹ÜÀíÈí¼þ£ºLSI´æ´¢¹ÜÀí¾Ö(LSA)¡¢StorCLI(ÃüÁîÐнӿÚ)¡¢HII(UEFIÈËÀà½Ó¿Ú»ù´¡ÉèÊ©) »º´æ±£»¤£º}CacheVault CVPM 05 ÎïÀíάÊý£ºµÍÆÊÃæ6.127Ó¢´çx2.712Ó¢´ç Ö÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.1 ¸ßËÙ»º´æ´æ´¢Æ÷£º2GB 2133 MHz DDR 4 SDRAM Ö§³Å×°ÖãºSAS/SATA£º240£¬NVMe£
- ²úÆ·ÌØÐÔ1£º²Ù×÷ζȣº0¡ãC-55¡ãC ¹¤×÷µçѹ(V)£º+12V+/-8%£¬3.3V+/-9% I/O´¦ÀíÆ÷/SAS¿ØÖÆÆ÷£ºSAS 3508Ë«ºËƬÉÏRAID(ROC) ±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö
LSI 9460-16i
- ÄÚÖýӿڣº4 Mini-SAS HD x4 SFF-8643
- ÆäËûÐÔÄÜ£º¹ÜÀíÈí¼þ£ºLSI´æ´¢¹ÜÀí¾Ö(LSA)¡¢StorCLI(ÃüÁîÐнӿÚ)¡¢HII(UEFIÈËÀà½Ó¿Ú»ù´¡ÉèÊ©) »º´æ±£»¤£ºCacheVault CVPM 05 ÎïÀíάÊý£ºµÍÆÊÃæ6.127Ó¢´çx2.712Ó¢´ç Ö÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.1 ¸ßËÙ»º´æ´æ´¢Æ÷£º4GB 2133 MHz DDR 4 SDRAM Ö§³Å×°ÖãºSAS/SATA£º240£¬NVMe£º
- ²úÆ·ÌØÐÔ1£º²Ù×÷ζȣº0¡ãCÖÁ55¡ãC ¹¤×÷µçѹ(V)£º+12V+/-8%£¬3.3V+/-9% I/O´¦ÀíÆ÷/SAS¿ØÖÆÆ÷£ºSAS 3516Ë«ºËƬÉÏRAID(ROC) ±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö
LSI MegaRAID SAS 9361-16i
- ºËÐÄ´¦ÀíоƬ£ºsas3316 RAIDоƬ
- RAID¹¦ÄÜ£ºRAID¼¶±ð0£¬1£¬5£¬6£¬10£¬50£¬60
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ×î¶àÁ¬½ÓÉ豸£ºÁ¬½Ó¶à´ï240¸öSATA»òSASÇý¶¯Æ÷
- ²å²ÛÀàÐÍ£ºPCI-E 3.0Ö÷»ú½Ó¿Ú
- ÆäËûÐÔÄÜ£º1¡¢ËÄÃÔÄãSAS ¸ü¶à²ÎÊý>>
LSI MegaRAID SAS 9271-8i
- ºËÐÄ´¦ÀíоƬ£ºLSI SAS2208
- RAID¹¦ÄÜ£ºRAID¼¶±ð0¡¢1¡¢5ºÍ6£¬ ¿ç½Ó10¡¢50ºÍ60
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º6Gb/s
- ×î¶àÁ¬½ÓÉ豸£º×î¶à128¸öSAS»òSATAÓ²ÅÌÇý¶¯Æ÷ºÍSSD
- ²å²ÛÀàÐÍ£ºPCI-E
- ϵͳƽ̨£ºÖ§³Ö¸÷Àà²Ù×÷ϵͳ£¬ÆäÖаüÀ¨ Microsoft Windows Vista/2008/Server 2003/2000/XP¡¢Linux¡¢Solaris£¨x86£©¡¢Netware¡¢FreeBSDÒÔ¼°VMwareµÈ¡£
- ÆäËûÐÔÄÜ£ºÁ½¸öMini-SAS ¸ü¶à²ÎÊý>>
LSI MegaRAID SAS 9240-8i
- RAID¹¦ÄÜ£ºRAID 0¡¢1¡¢5¡¢10¡¢50ºÍJBODģʽ
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º6Gb/s
- ͨµÀÊý£º8
- ×î¶àÁ¬½ÓÉ豸£ºÖ§³Ö¶à´ï64¸öÎïÀíÉ豸
- ²å²ÛÀàÐÍ£ºPCI
- ÆäËûÐÔÄÜ£º2¸öx4 Mini-S ¸ü¶à²ÎÊý>>
LSI MegaRAID SAS 9361-24i
- ºËÐÄ´¦ÀíоƬ£ºsas3324 RAIDоƬ
- RAID¹¦ÄÜ£ºRAID¼¶±ð0£¬1£¬5£¬6£¬10£¬50£¬60
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ×î¶àÁ¬½ÓÉ豸£ºÁ¬½Ó¶à´ï240¸öSATA»òSASÇý¶¯Æ÷
- ²å²ÛÀàÐÍ£ºPCI-E 3.0Ö÷»ú½Ó¿Ú
- ÆäËûÐÔÄÜ£º1¡¢ÁùÃÔÄãSAS ¸ü¶à²ÎÊý>>
LSI 9400-16i
- ÆäËûÐÔÄÜ£ºÉúÃüÖÜÆÚ£ºÖ÷¶¯ Ö÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.1 ÎïÀíάÊý£ºµÍÆÊÃæ6.127Ó¢´çx 2.712Ó¢´ç Ö§³Å×°ÖãºSAS/SATA£º1024£»NVMe£º24 ÄÚ²¿Á¬½ÓÆ÷£º4 Mini-SAS HD x4 SFF-8643 ²Ù×÷ζȣº0¡ãC-55¡ãC ¹¤×÷µçѹ£º+12V+/-8%£¬3.3V+/-9% ¹¤×÷ʪ¶È£º20%-80%²»Äý½á ÍмܣºÈ«¸ß
- ²úÆ·ÌØÐÔ1£º±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö ¹ÜÀíÈí¼þ£ºLSI´æ´¢¹ÜÀí¾Ö(LSA)¡¢StorCLI(ÃüÁîÐнӿÚ)¡¢HII(UEFIÈËÀà½Ó¿Ú»ù´¡ÉèÊ©)
LSI MegaRAID SAS 9341-8i
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£ºÐ¾Æ¬ÉϵÄRAID¿ØÖÆÆ÷£ºPOWER476 ¹ÜÀíÈí¼þ£ºMegaRAID Storage Manager£¬StorCLI £¨command-line interface£© ÎïÀí³ß´ç£ºLow Profile£¨6.6"¡Á2.536"£©
- ²úÆ·ÌØÐÔ1£ºÖ§³ÖRAID¼¶±ð£ºNon-RAID£¨JBOD Mode£©£º64 RAID 0£º32 per volume RAID 1£º2 per volume plus hot spare RAID 5£º32 per volume RAID 10£º32 per volume RAID 50£º32 per volume
LSI HBASAS 9300-8i
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£º¿¨ÍâÐÍ£º4U£¬2U£¬¸ß¶È¼æÈÝ Ö÷ÏßÀàÐÍ£ºPCI-E 3.0£¬PCI-E8X ÎïÀí³ß´ç£ºLow profile£¨2.6"¡Á6.0"£© É豸֧³Ö£º1024·ÇRAIDµÄSAS/SATAÉ豸
LSI MegaRAID SAS 9211-8i
- RAID¹¦ÄÜ£º¼¯³É RAID 0¡¢1¡¢1E ºÍ 10
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º6Gb/s
- ͨµÀÊý£º8
- ×î¶àÁ¬½ÓÉ豸£ºÖ§³Ö¶à´ï 256 ¸ö SAS »ò SATA ¶ËµãÉ豸
- ²å²ÛÀàÐÍ£ºPCI
- ϵͳƽ̨£ºMicrosoft Windows¡¢Linux (SuSE¡¢Red Hat)¡¢Solaris¡¢VmwareµÈ
- ÆäËûÐÔÄÜ£ºPCI×ÜÏߣº8ÐÅ ¸ü¶à²ÎÊý>>
LSI 9400-8i
- ÄÚÖýӿڣº2 HD Mini-SAS SFF 8643(ÎÔʽ°²×°)
- ϵͳƽ̨£ºWindows£¬Linux£¬VMware
- ÆäËûÐÔÄÜ£ºÖ÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.1 ÎïÀíάÊý£ºµÍÆÊÃæ6.127Ó¢´çx2.712Ó¢´ç Ö§³Å×°ÖãºSAS/SATA£º1024£»NVMe£º24 ²Ù×÷ζȣº0¡ãC-55¡ãC ¹¤×÷µçѹ£º+12V+/-8%£¬3.3V+/-9% PCIµçÔ´£ºµäÐÍ£º10.05W µçÀÂÖ§¼Ü£º¶Û»¯Í I/O¿ØÖÆÆ÷£ºSAS 3408 MTBF£º40¡ãC>4£¬500£¬000Сʱ
- ²úÆ·ÌØÐÔ1£º¹¤×÷ʪ¶È£º20%-80%²»Äý½á ÍмܣºÈ«¸ßµÍÂÖÀª ±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö
LSI MegaRAID SAS 9270-8i
- ºËÐÄ´¦ÀíоƬ£ºLSI SAS2208
- RAID¹¦ÄÜ£ºRAID¼¶±ð0¡¢1¡¢5ºÍ6£¬ ¿ç½Ó10¡¢50ºÍ60
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º6Gb/s
- ×î¶àÁ¬½ÓÉ豸£º×î¶à128¸öSAS»òSATAÓ²ÅÌÇý¶¯Æ÷ºÍSSD
- ²å²ÛÀàÐÍ£ºPCI-E
- ϵͳƽ̨£ºÖ§³Ö¸÷Àà²Ù×÷ϵͳ£¬ÆäÖаüÀ¨ Microsoft Windows Vista/2008/Server 2003/2000/XP¡¢Linux¡¢Solaris£¨x86£©¡¢Netware¡¢FreeBSDÒÔ¼°VMwareµÈ¡£
- ÆäËûÐÔÄÜ£ºÁ½¸öMini-SAS ¸ü¶à²ÎÊý>>
LSI 9380-8e
- Êý¾Ý´«ÊäÂÊ£ºÃ¿¸ö¶Ë¿Ú¿É´ï12 Gb/s
- ϵͳƽ̨£ºMicrosoft Windows Vista/2008/Server 2003/2000/XP¡¢Linux¡¢Solaris(X86)¡¢Neware¡¢FreeBSD¡¢VMware
- ÆäËûÐÔÄÜ£ºÉúÃüÖÜÆÚ£ºÖ÷¶¯ RAID¿ØÖÆÆ÷£ºLSISAS 3108Ë«ºËRAIDоƬ(ROC) ÍⲿÁ¬½ÓÆ÷£º2 Mini-SAS HD SFF 8644 RAID¹ÜÀíÈí¼þ LSA(LSI´æ´¢¹ÜÀí¾Ö)¡¢MegaRAID´æ´¢¹ÜÀíÆ÷¡¢StorCLI(ÃüÁîÐнӿÚ)¡¢CTRL-R(BIOSÅäÖÃʵÓÃÐò)¡¢HII(UEFIÈ˹¤½Ó¿Ú»ù´¡ÉèÊ©) ÎïÀíάÊý MD2µÍÆÊÃæ(6.6Ó¢´çx 2.536Ó¢´
- ²úÆ·ÌØÐÔ1£ºÖ÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.0 ¸ßËÙ»º´æ´æ´¢Æ÷£º1GB 1866 MHz DDRIII SDRAM Êý¾Ý´«ÊäÂÊ£ºÃ¿¸ö¶Ë¿Ú¿É´ï12 Gb/s Ö§³Å×°Öãº×î¶à240¸öSATAºÍ/»òSASÉ豸 ±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö
LSI 9217-8i
- ½Ó¿Ú£º6GB/sSAS-2¼æÈÝ
- ÄÚÖýӿڣº2 Mini-SAS SFF 8087
- ͨµÀÊý£ºX8³µµÀPCI Express 3.0
- ϵͳƽ̨£ºMicrosoft Windows£¬Linux(SUSE£¬Red Hat)£¬Solaris£¬VMware£¬FreeBSD
- ÆäËûÐÔÄÜ£ºÉúÃüÖÜÆÚ£ºÖ÷¶¯ ÎïÀíάÊý£ºµÍÂÖÀª(2.6Ó¢´çx6.6Ó¢´ç) Ö§³Å×°Öãº×î¶à256¸öSASºÍ/»òSATAÉ豸 ÈÚºÏMPTÖ§¼Ü£ºÈÚºÏMPT2.0 ²Ù×÷ζȣº0¡ãC-55¡ãC ¹¤×÷ʪ¶È£º5%-90%²»Äý½á ¹¤×÷µçѹ£º+12V+/-8%£¬3.3V+/-8% PCIµçÔ´£º9.8WµäÐÍ£¬ÆøÁ÷200 LFM µçÀÂÖ§¼Ü£º¶Û»¯Í I/O¿ØÖÆÆ÷£ºLSI
- ²úÆ·ÌØÐÔ1£ºMTBF£º>2 000 000Сʱ ¹¤×÷ʪ¶È£º5%-90%²»Äý½á ¼à¹ÜÈÏÖ¤£º°Ä´óÀûÑÇ/ÐÂÎ÷À¼(AS/NZS 3548)¡¢¼ÓÄôó(ICES-003)¡¢EMC£ºB-US(CFR 47¡¢P15B)¡¢Å·ÖÞ(EN55022/EN55024)¡¢ÈÕ±¾(V-3/02.04)¡¢RoHS¡¢°²È«£ºEN 60950¡¢WEEE
LSI MegaRAID SAS 8708EM2
- RAID¹¦ÄÜ£ºRAID 0¡¢1¡¢5 ºÍ 6
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º3Gb/s
- ×î¶àÁ¬½ÓÉ豸£º32¸ö
- ²å²ÛÀàÐÍ£ºPCI-E
LSI MegaRAID SAS 8708ELP
- ºËÐÄ´¦ÀíоƬ£ºLSISAS1078
- RAID¹¦ÄÜ£ºRAID 0¡¢1¡¢5¡¢6,RAIDÀ©Õ¹10¡¢50¡¢60
- ½Ó¿Ú£ºSerial ATA/SAS
- Êý¾Ý´«ÊäÂÊ£º3Gb/s
- ²å²ÛÀàÐÍ£ºPCI-E
- ϵͳƽ̨£ºMicrosoft Windows Server 2003/2000/XP¡¢Linux
LSI MegaRAID SAS 9261-8i
- ºËÐÄ´¦ÀíоƬ£ºLSISAS2108 ROC
- RAID¹¦ÄÜ£ºRAID ¼¶±ð£º0¡¢1¡¢5 ºÍ 6 RAID ¿ç½Ó£º10¡¢50 ºÍ 60 ÔÚÏß RAID ¼¶Ç¨ÒÆ (RLM)
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º6Gb/s
- ×î¶àÁ¬½ÓÉ豸£º×î¶à¿ÉÁ¬½Ó 32 ¸ö SATAºÍ/»ò SAS É豸
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£º2¸öMini-SAS SFF-8087 x4 Á¬½ÓÆ÷£¨Ë®Æ½°²×°£© 512MB DDRII ¸ßËÙ»º´æ(800MHz) ¿ÉÑ¡µç³Ø±¸Óõ¥Ôª£¨Ö±½Ó°²×°£© ÔÚÏßÈÝÁ¿À©³ä(OCE) ÀûÓà SSD Guard Ìṩ SSD Ö§³Ö
- ²úÆ·ÌØÐÔ1£º¾ßÓпɻָ´ÈÈ ¸ü¶à²ÎÊý>>
LSI HBASAS 9300-16i
- ½Ó¿Ú£ºSerial SATA/SAS
- Êý¾Ý´«ÊäÂÊ£º12Gb/s
- ²å²ÛÀàÐÍ£ºPCI-E
- ÆäËûÐÔÄÜ£º¿¨ÍâÐÍ£º4U£¬2U£¬¸ß¶È¼æÈÝ Ö÷ÏßÀàÐÍ£ºPCI-E 3.0£¬PCI-E8X ÎïÀí³ß´ç£ºLow profile£¨2.6"¡Á6.0"£© É豸֧³Ö£º1024·ÇRAIDµÄSAS/SATAÉ豸
LSI 9300-8e
- Êý¾Ý´«ÊäÂÊ£º12 GB/ssas-3¼æÈÝ
- ϵͳƽ̨£ºMicrosoft Windows¡¢Linux(SUSE¡¢Red Hat)¡¢Solaris¡¢VMware¡¢FreeBSD
- ÆäËûÐÔÄÜ£ºÉúÃüÖÜÆÚ£ºÖ÷¶¯ Ö÷»ú×ÜÏßÀàÐÍ£ºX8³µµÀPCI Express 3.0 ÎïÀíάÊý£ºµÍÂÖÀª(2.6Ó¢´çx6.0Ó¢´ç) Ö§³Å×°Öãº1024¸ö·ÇRAID SAS/SATAÉ豸 ÍⲿÁ¬½ÓÆ÷£º2Mini-SAS HD SFF 8644 ÈÚºÏMPTÖ§¼Ü£º¾Û±äMPT 2.5 ²Ù×÷ζȣº0¡ãC-55¡ãC ¹¤×÷µçѹ£º+12V+/-8%£¬3.3V+/-9% PCIµçÔ´£º14.5W
- ²úÆ·ÌØÐÔ1£ºµçÀÂÖ§¼Ü£ºÎÞÔ´Í£¬ÓÐÔ´¹âѧ I/O¿ØÖÆÆ÷£ºLSI SAS 3008 MTBF£º>280ÍòСʱ ¹¤×÷ʪ¶È£º5%-90%²»Äý½á ÍмܣºÈ«¸ßµÍÂÖÀªÅÅÆø ±£ÐÞ£º3Ä꣬Ãâ·Ñ¼¼ÊõÖ§³Ö ¹ÜÀíÈí¼þ£ºMegaRAID´æ´¢¹ÜÀíÆ÷(MSM)¡¢StorCLI(ÃüÁîÐнӿÚ)¡¢LSI´æ´¢¹ÜÀí¾Ö(LSA)¡¢HII UEFIÈË»ú½çÃæ»ù´¡ÉèÊ©¡¢CTRL-R
LSI cvm02-2G
- ÆäËûÐÔÄÜ£ºMPN&ÐòPN£º05-25444-00 ÃèÊö/¼æÈÝ¿ØÖÆÆ÷£º9361ºÍ9380ϵÁÐCacheVault Flash Cache±£»¤Ä£¿é RAID¿ØÖÆÆ÷¿¨µÄ»º´æ±£»¤ ·ÀֹͣµçʱµÄÊý¾ÝËðºÄ
RAID¿¨Æ·ÅƱ¨¼Û´óÈ«
- LSIRAID¿¨(46)
- BroadcomRAID¿¨(8)
- AdaptecRAID¿¨(48)
- HighPointRAID¿¨(27)
- ÂóÎÖRAID¿¨(1)
- PROMISERAID¿¨(4)
- ÆߺÓRAID¿¨(1)
- ¹ÅºÌRAID¿¨()
- E-COMRAID¿¨()
- ÎÀÐÇÓ°ÔºRAID¿¨()
- PaxyanRAID¿¨()
- WISETIGERRAID¿¨()
- ´÷ά˹RAID¿¨()
- ´¨ÕýRAID¿¨()
- °¬Â×˹RAID¿¨()
- À××ðRAID¿¨()
- iEagerRAID¿¨()
- ±¼ÀÊRAID¿¨()